Mitsubishi Electronics QD75MH2 ユーザーズマニュアル
9 - 42
MELSEC-Q
9 MAJOR POSITIONING CONTROL
[2] 4-axis linear interpolation control (INC linear 4)
Operation chart
In the incremental system 4-axis linear interpolation control, using an address
established by a machine OPR in the 4-axis coordinate plane, a linear interpolation
positioning is carried out from the current stop position (start point address) to a
position at the end of the movement amount set in the "
established by a machine OPR in the 4-axis coordinate plane, a linear interpolation
positioning is carried out from the current stop position (start point address) to a
position at the end of the movement amount set in the "
Da.6
Positioning
address/movement amount". The movement direction depends on the sign (+ or -)
of the movement amount.
of the movement amount.
Restrictions
An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning
operation.
machine will immediately stop if the error is detected during a positioning
operation.
•
When the movement amount for each axis exceeds "1073741824 (=2
30
)"
An "outside linear movement amount range error (error code: 504)" will occur at
the positioning start.
(The maximum movement amount that can be set in "
the positioning start.
(The maximum movement amount that can be set in "
Da.6
Positioning
address/movement amount" is "1073741824 (=2
30
)".)