10   HIGH-LEVEL POSITIONING CONTROL 
 
The setting requirements and details of the following "condition data" "
 Da.16 
" to 
"
 Da.19 
" setting items differ according to the "
 Da.15 
Condition target" setting.  
The following shows the "
 Da.16 
" to "
 Da.19 
" setting items corresponding to the 
"
 Da.15 
Condition target". 
 
Other setting 
item 
 Da.15   
Setting item 
 Da.16   
Condition operator 
 Da.17   
Address 
 Da.18   
Parameter 1 
 Da.19   
Parameter 2 
01
H
: Device X 
0 to 1F
H
 (bit No.) 
02
H
: Device Y 
07
H
 :  DEV=ON 
08
H
 :  DEV=OFF 
– 
0 to 1F
H
 (bit No.) 
– 
03
H
: Buffer memory  
(1 word) 
04
H
: Buffer memory  
(2 words) 
01
H
 : 
=P1 
02
H
 : 
≠P1 
03
H
 : 
≤P1 
04
H
 : 
≥P1 
05
H
 : P1≤
≤P2 
06
H
 : 
≤P1, P2 ≤
 
Buffer 
memory 
address 
P1 (numeric value) 
P2 (numeric value) 
(Set only when "
Da.16
" is 
[05
H
] or [06
H
].) 
Low-order 16 
bits 
Axis 1 
positioning 
data No. 
Low-order 16 
bits 
Axis 3 
positioning 
data No. 
05
H
: Positioning data  
No. 
10
H
 :  Axis 1 designation 
20
H
 :  Axis 2 designation 
30
H
 :  Axis 1 and axis 2 
designation 
40
H
 :  Axis 3 designation 
50
H
 :  Axis 1 and axis 3 
designation  
60
H
 :  Axis 2 and axis 3 
designation 
70
H
 :  Axis 1, axis 2 and 
axis 3 designation 
80
H
 :  Axis 4 designation 
90
H
 :  Axis 1 and axis 4 
designation 
A0
H
 :  Axis 2 and axis 4 
designation 
B0
H
 :  Axis 1, axis 2 and 
axis 4 designation  
C0
H
 :  Axis 3 and axis 4 
designation 
D0
H
 :  Axis 1, axis 3 and 
axis 4 designation  
E0
H
 :  Axis 2, axis 3 and 
axis 4 designation 
— 
High-order 16 
bits 
Axis 2 
positioning 
data No. 
High-order 16 
bits 
Axis 4 
positioning 
data No. 
 
– 
:  Setting not required (Setting value will be ignored. Use the initial value or a value within the setting range.) 
  :  Value stored in buffer memory designated in  Da.17  . 
 
:  Refer to Section 5.5 "List of condition data" for the setting contents. 
 
Judgment whether the condition operator is "=" or "=” at the start of wait. 
Judgment on data is carried out for each control cycle of the QD75MH. Thus, in the 
judgment on the data such as current feed value which varies continuously, the 
operator "=" may not be detected.  If this occurs, use a range operator.