Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
11 - 3 
MELSEC-Q
 
11   MANUAL CONTROL 
 
[3]   Manual pulse generator operation 
"Manual pulse generator operation" is a control method in which positioning is 
carried out in response to the No. of pulses input from a manual pulse generator 
(the No. of input pulses is output).  This operation is used for manual fine 
adjustment, etc., when carrying out accurate positioning to obtain the positioning 
address.  
 
M
Movement in response 
to the command pulses
QD75MH
Output pulses
Manual pulse generator 
Pulse input
 
Fig. 11.3 Manual pulse generator control 
 
 Manual control sub functions 
 
Refer to Section 3.2.4 "Combination of QD75MH major functions and sub 
functions" for details on "sub functions" that can be combined with manual control. 
Also refer to Chapter 12 "Control sub functions" for details on each sub function.  
 
 Carrying out manual control from peripheral devices 
 
"JOG operation", "Inching operation" and enabling/disabling of the "manual pulse 
generator operation" can be executed from GX Configurator-QP test mode.  
Refer to GX Configurator-QP Operating Manual for details on manual control from 
GX Configurator-QP.  
 
 Monitoring manual control  
 
Refer to Section 5.6 "List of monitor data" when directly monitoring the buffer 
memory using GX Developer.  
Also refer to GX Configurator-QP Operating Manual when monitoring with the 
monitor functions of GX Configurator-QP.