Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
11 - 16 
MELSEC-Q
 
11   MANUAL CONTROL 
 
  When the "JOG start signal" is turned ON immediately after the stop signal 
OFF (within 100ms) 
 
When the "JOG start signal" is turned ON immediately after the stop signal OFF 
(within 100ms), it will be ignored and the JOG operation will not be carried out.  
 
ON
Axis stop signal
                     [Y4, Y5, Y6, Y7]
OFF
ON
OFF
100ms
A JOG start signal OFF
ON while the stop signal is 
ON will be ignored.
Forward run JOG operation 
Forward run JOG start signal
                     [Y8, YA, YC, YE]
 
Fig. 11.11 Operation when the JOG start signal is turned ON immediately after the stop signal OFF