Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
11 - 28 
MELSEC-Q
 
11   MANUAL CONTROL 
 
 Restricted items 
 
A manual pulse generator is required to carry out manual pulse generator 
operation.  
 
 Precautions during operation 
 
The following details must be understood before carrying out manual pulse 
generator operation.  
 
(1)  The speed during manual pulse generator operation is not limited by the 
"
Pr.8
 Speed limit value".  
(2)  If the "
Cd.21
 Manual pulse generator enable flag" is turned ON while the 
QD75MH is BUSY (BUSY signal ON), a warning will occur (warning code 100: 
start during operation).  
(3)  If a stop factor occurs during manual pulse generator operation, the operation 
will stop, and the BUSY signal will turn OFF.  
At this time, the "
Cd.21
 Manual pulse generator enable flag" will be left ON, 
but manual pulse generator operation will not be possible. To carry out manual 
pulse generator operation again, measures must be carried out to eliminate 
the stop factor. Once eliminated, the operation can be carried out again by 
turning the "
Cd.21
 Manual pulse generator enable flag" ON   OFF   ON.  
(4)  Pulses will not be output if an error occurs when the manual pulse generator 
operation starts.  
 
Important 
 
When the speed command beyond the following calculated value is input into the 
positioning module using the manual pulse generator, the servo error "2035: data 
error” (detection of the alarm "35: command frequency error at the servo amplifier) 
may occur. 
The following calculation formula is used to judge whether or not an error will occur. 
Output pulse of manual pulse generator  
× 
 Magnification  
×
  Electronic gear 
(number of pulses per revolution/movement amount per revolution)  
×
  Number of 
revolutions of manual pulse generator for one second  =  Speed command pps 
When the speed command is larger than 62914560pps (63Mpps), an error may 
occur. 
[Calculation example for setting] 
           100pls   
×
   50   
×
   262144   /   500   
×
   2                         =104857600pps 
                                                             (Speed of two revolutions for one second)
  =104Mpps
 
                                                                                       Occurrence of data error 
With detection of an alarm at the servo amplifier, "2035: data error" will be given 
when the command from the positioning module is larger than 63Mpps. 
Because the command is issued according to the pulse input irrelevant of the 
speed limit setting when the manual pulse generator is used for entry, "2035: data 
error" will occur if a speed command, which the servo amplifier cannot follow up, is 
input. 
In the case of a high setting magnification, there is a high possibility of error 
occurrence. Therefore, perform the setting so that the setting magnification of the 
manual pulse generator decreases to the level where "2035: data error" will not 
occur.