Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
12 - 5 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
(2)  OPR retry operation when the workpiece is outside the range between the 
upper and lower limits.  
 
  1)  When the direction from the workpiece to the OP is the same as the "
Pr.44
 OPR direction", a 
normal machine OPR is carried out. 
Pr. 44  OPR direction 
Hardware upper limit switch 
Hardware lower limit switch
Movement range
Machine OPR start
OP
Zero signal 
Near-point dog
 
  2)  When the direction from the workpiece to the OP is the opposite direction from the "
Pr.44
 OPR 
direction", the operation carries out a deceleration stop when the near-point dog turns OFF, and 
then carries out a machine OPR in the direction set in "
Pr.44
 OPR direction". 
Pr. 44  OPR direction 
Near-point dog
Hardware upper limit switch 
Hardware lower limit switch
Movement range
Machine OPR start
OP
Zero signal 
 
 
                       
 In the a
bove example 1) and 2), "0: Positive direction" is set in " Pr.44 OPR direction" 
REMARK 
      
 When the "0: Positive direction" is selected in "
Pr.44
OPR direction", the upper limit switch is 
set to the limit switch in the OPR direction. 
      
 When the "1: Negative direction" is selected in "
Pr.44
OPR direction", the lower limit switch is 
set to the limit switch in the OPR direction. 
      
 If inverting the install positions of upper/lower limit switches, hardware stroke limit function cannot 
be operated properly. 
If problem is found when "
Pr.114
 Rotation direction selection" and the wiring for the upper/lower 
limit switch are checked. 
Fig. 12.2 OPR retry operation from on limit (limit signal OFF)