Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
12 - 26 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
[2]   Control details 
The following drawing shows the operation of the torque limit function.  
 
300
250
100
150
0
0
0
0
0
0
300
300
100
150
150
 1: The torque limit setting value or torque output setting value becomes effective at the PLC READY signal (Y0) rising edge 
     (however, after the servo turned ON.)
     If the torque output setting value is "0" or larger than the torque limit setting value, the torque limit setting value will be its value.:
 2: The torque limit setting value or torque output setting value becomes effective at the start signal (Y10)rising edge.
     If the torque output setting value is "0" or larger than the torque limit setting value, the torque limit setting value, the torque limit setting 
     value will be its value.
 3: The torque change value is cleared to "0" at the start signal (Y10) rising edge. 
Each operations
PLC READY signal (Y0)
All axis servo ON (Y1)
Start signal (Y10)
Torque limit setting
value (26)
Torque output setting
value (1552)
New toruque value
(1525)
Torque limit stored
value (826)
Pr.17
Cd.101
Cd.22
Md.35
1
1
2
2
2
3
3
3
 
Fig. 12.12 Torque limit function operation 
 
[3]   Precautions during control 
(1)  When limiting the torque at the "
Pr.17
 Torque limit setting value", confirm 
that "
Cd.22
 New torque value" is set to "0". If this parameter is set to a 
value besides "0", the "
Cd.22
 New torque value" will be validated, and the 
torque will be limited at that value. (Refer to Section 12.5.4 "Torque change 
function" for details about the "new torque value".) 
(2)  When the “
Pr.54
OPR torque limit value “exceeds the “
Pr.17
Torque 
limit setting value”, an error occurs. (Error code: 995) 
 
(3)  When the operation is stopped by torque limiting, the droop pulse will remain 
in the deviation counter.  If the load torque is eliminated, operation for the 
amount of droop pulses will be carried out.