12 - 97 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
[3] Deceleration start flag function setting method 
 
To use the "deceleration start flag function", set "1" to the following control data 
using a PLC program. 
The set data is made valid on the rising edge (OFF to ON) of the PLC READY 
signal [Y0]. 
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address 
 Cd
.41
 
 
Deceleration start 
flag valid 
 
Set whether the deceleration start flag function 
is made valid or invalid. 
0: Deceleration start flag invalid 
1: Deceleration start flag valid 
1905 
 
                  Refer to Section 5.7 "List of control data" for details on the setting details. 
 
[4] Checking of deceleration start flag 
 
The "deceleration start flag" is stored into the following buffer memory addresses. 
 
Buffer memory address 
Monitor item 
Monitor 
value 
Storage details 
Axis 
Axis 
Axis 
Axis 
 Md
.48
 
 
Deceleration start 
flag 
 
0: Status other than below 
1: Status from deceleration start to next 
operation start or manual pulse generator 
operation enable 
899 999 1099 1199 
 
                  Refer to Section 5.6 "List of monitor data" for information on the storage details.