IBM Type 7977 ユーザーズマニュアル

ページ / 124
Using
 
the
 
baseboard
 
management
 
controller
 
The
 
baseboard
 
management
 
controller
 
provides
 
environmental
 
monitoring
 
for
 
the
 
server.
 
If
 
environmental
 
conditions
 
exceed
 
thresholds
 
or
 
if
 
system
 
components
 
fail,
 
the
 
baseboard
 
management
 
controller
 
lights
 
LEDs
 
to
 
help
 
you
 
diagnose
 
the
 
problem
 
and
 
also
 
records
 
the
 
error
 
in
 
the
 
system
 
event/error
 
log.
 
The
 
baseboard
 
management
 
controller
 
also
 
provides
 
the
 
following
 
remote
 
server
 
management
 
capabilities
 
through
 
the
 
OSA
 
SMBridge
 
management
 
utility
 
program:
 
v
   
Command-line
 
interface
 
(IPMI
 
Shell)
 
The
 
command-line
 
interface
 
provides
 
direct
 
access
 
to
 
server
 
management
 
functions
 
through
 
the
 
IPMI
 
protocol.
 
Use
 
the
 
command-line
 
interface
 
to
 
issue
 
commands
 
to
 
control
 
the
 
server
 
power,
 
view
 
system
 
information,
 
and
 
identify
 
the
 
server.
 
You
 
can
 
also
 
save
 
one
 
or
 
more
 
commands
 
as
 
a
 
text
 
file
 
and
 
run
 
the
 
file
 
as
 
a
 
script.
 
v
   
Serial
 
over
 
LAN
 
Establish
 
a
 
Serial
 
over
 
LAN
 
(SOL)
 
connection
 
to
 
manage
 
servers
 
from
 
a
 
remote
 
location.
 
You
 
can
 
remotely
 
view
 
and
 
change
 
the
 
BIOS
 
settings,
 
restart
 
the
 
server,
 
identify
 
the
 
server,
 
and
 
perform
 
other
 
management
 
functions.
 
Any
 
standard
 
Telnet
 
client
 
application
 
can
 
access
 
the
 
SOL
 
connection.
Enabling
 
and
 
configuring
 
SOL
 
using
 
the
 
OSA
 
SMBridge
 
management
 
utility
 
program
 
To
 
enable
 
and
 
configure
 
the
 
server
 
for
 
SOL
 
by
 
using
 
the
 
OSA
 
SMBridge
 
management
 
utility
 
program,
 
you
 
must
 
update
 
and
 
configure
 
the
 
BIOS
 
code;
 
update
 
and
 
configure
 
the
 
baseboard
 
management
 
controller
 
(BMC)
 
firmware;
 
update
 
and
 
configure
 
the
 
Ethernet
 
controller
 
firmware;
 
and
 
enable
 
the
 
operating
 
system
 
for
 
an
 
SOL
 
connection.
 
BIOS
 
update
 
and
 
configuration
 
Complete
 
the
 
following
 
steps
 
to
 
update
 
and
 
configure
 
the
 
BIOS
 
code
 
to
 
enable
 
SOL:
 
1.
   
Update
 
the
 
BIOS
 
code:
 
a.
   
Download
 
the
 
latest
 
version
 
of
 
the
 
BIOS
 
code
 
from
 
 
b.
   
Update
 
the
 
BIOS
 
code,
 
following
 
the
 
instructions
 
that
 
come
 
with
 
the
 
update
 
file
 
that
 
you
 
downloaded.
2.
   
Update
 
the
 
BMC
 
firmware:
 
a.
   
Download
 
the
 
latest
 
version
 
of
 
the
 
BMC
 
firmware
 
from
 
 
b.
   
Update
 
the
 
BMC
 
firmware,
 
following
 
the
 
instructions
 
that
 
come
 
with
 
the
 
update
 
file
 
that
 
you
 
downloaded.
3.
   
Configure
 
the
 
BIOS
 
settings:
 
a.
   
Restart
 
the
 
server
 
and
 
press
 
F1
 
when
 
you
 
are
 
prompted
 
to
 
start
 
the
 
Configuration/Setup
 
Utility
 
program.
 
b.
   
Select
 
Devices
 
and
 
I/O
 
Ports;
 
then,
 
make
 
sure
 
that
 
the
 
values
 
are
 
set
 
as
 
follows:
 
v
   
Serial
 
Port
 
A:
 
Auto-configure
 
v
   
Serial
 
Port
 
B:
 
Auto-configure
c.
   
Select
 
Remote
 
Console
 
Redirection;
 
then,
 
make
 
sure
 
that
 
the
 
values
 
are
 
set
 
as
 
follows:
 
 
Chapter
 
4.
 
Configuring
 
the
 
server
 
43