Zebra Technologies 105SL ユーザーズマニュアル

ページ / 130
Troubleshooting
Printer Diagnostics
11342L Rev. 8 6/4/2004
105SL User Guide
89
FEED and PAUSE Self Test
Performing this self test temporarily resets the printer configuration to the factory default 
values. These values are active only until power is turned off unless you save them 
permanently in memory.
To perform a FEED and PAUSE self test, complete these steps:
1.
Turn Off (O) the printer.
2.
Press and hold FEED and PAUSE
 
while turning the power On (I). Hold FEED and 
PAUSE until the DATA light turns off.
No labels print at the end of this test.
This test is controlled from the front panel display (see 
 shows a typical printout from this test. Turn off the power to exit this self test and 
return to normal operation.
Figure 49 • Communications Diagnostics Test Label
Additional Printer Diagnostics
Additional diagnostic tests are available for this printer. See the Maintenance Manual for 
information about these additional tests.
Note • 
The communications test label prints upside-down.