Zebra Technologies 105SL ユーザーズマニュアル
Printer Operation
Adjust and Calibrate Sensors
11342L Rev. 8 6/4/2004
105SL User Guide
37
7.
Close the printhead, trapping the ribbon in this position.
8.
Press the (+) key. The LCD shows “CALIBRATING PLEASE WAIT.”
9.
When this part of the calibration process is completed, the LCD reads “RELOAD ALL
CONTINUE.”
CONTINUE.”
10.
Open the printhead. Pull the liner until a label is positioned between the media sensors.
11.
Return the ribbon to its proper position.
12.
Close the printhead. Press the (+) key to perform the next part of the calibration sequence.
“MEDIA AND RIBBON CALIBRATE” displays. The printer is calibrated when the
media stops feeding.
“MEDIA AND RIBBON CALIBRATE” displays. The printer is calibrated when the
media stops feeding.
13.
Press SETUP/EXIT to leave Setup Mode. Choose “permanent” when SAVE CHANGES
displays.
displays.
14.
Press NEXT/SAVE to save the changes.
The printer does a calibration equivalent to pressing
The printer does a calibration equivalent to pressing
CALIBRATE
; during this process,
the printer determines the label length. To see the new readings on the new scale, print a
sensor profile.
sensor profile.