CAN BE USED AS
• Air Computer
• Nitrox Computer
NO DECOMPRESSION MODEL
Basis:
• Modified Haldanean Algorithm
• 12 tissue compartments
Data Base:
• Diving Science and Technology (DSAT) - Rogers/Powell
Performance:
• Tissue compartment halftimes (mins.) Spencer’s “M”
values
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
• Reciprocal subsurface elimination
• 60 minute surface credit control for compartments faster
than 60 minutes
• Tissue compartments tracked up to 24 hours after last
dive
Decompression Capabilities:
• Decompression stop ceilings at 10, 20, 30, 40, 50,  60 FT
(3, 6, 9, 12, 15, 18 M)
Altitude Algorithm:
• Based on NOAA tables
Oxygen Exposure Limits:
• Based on NOAA tables
OPERATIONAL MODES
• Activation/Diagnostic
• Serial Number
• Surface
• Time to Fly Countdown
• Desaturation Countdown
• Pre Dive Planning Sequence
(30 to 190 FT / 9 to 57 M)
• Dive Log (Preview, Dive Data, O2 Data)
• Reset
• Set FO2 (Air, 21 to 50%)
• Set Wet Activation (On / Off)
• Set Units of Measure (Imperial / Metric)
• Set Hour Format (12 / 24)
• Set Time (Hour, Minute)
• Set PO2 Alarm (1.20 to 1.60 ATA)
• Set FO2 50% Default (On/Off)
• No Decompression Dive:
• Main #1 (Depth, Dive Time Remaining, Bar
Graphs)
• Main #2 (Depth, Dive Time Remaining,
Max Depth, Elapsed Dive Time, Bar Graphs)
• Main #3 (Depth, Dive Time Remaining,
Temperature, Time of Day, Bar Graphs)
• Main #4 -if nitrox dive  (Depth, Dive Time
Remaining, Current PO2, Bar Graphs)
• Safety Stop - for dives deeper than 30 FT (9 M)
Depth, Stop Depth 15 FT/4.5 M, Stop Time 3:00
minutes, Dive Time Remaining, Bar Graphs)
SPECIFICATIONS