Siemens PANEL PC 877 ユーザーズマニュアル

ページ / 288
Detailed descriptions 
 
17.2 Bus board 
 
SIMATIC Panel PC 877 
17-28
 
Operating instructions, Release 07/2006, A5E00877780-01 
Pin No. 
Abbreviation 
Type* 
Pin No. 
Abbreviation 
Type 
C1 
-SBHE 
D1 
-MEMCS16 
C2 
LA 23 
I/O 
D2 
-IOCS16 
C3 
LA 22 
I/O 
D3 
IRQ 10 
C4 
LA 21 
I/O 
D4 
IRQ 11 
C5 
LA 20 
I/O 
D5 
IRQ 12 
C6 
LA 19 
I/O 
D6 
IRQ 13 
C7 
LA 18 
I/O 
D7 
IRQ 14 
C8 
LA 17 
I/O 
D8 
-DACK0 
C9 
-MEMR 
I/O 
D9 
DRQ 0 
C10 
-MEMW 
I/O 
D10 
-DACK5 
C11 
SD 08 
I/O 
D11 
DRQ 5 
C12 
SD 09 
I/O 
D12 
-DACK6 
C13 
SD 10 
I/O 
D13 
DRQ 6 
C14 
SD 11 
I/O 
D14 
-DACK7 
C15 
SD 12 
I/O 
D15 
DRQ 7 
C16 
SD 13 
I/O 
D16 
+ 5V 
VCC 
C17 
SD 14 
I/O 
D17 
-MASTER 
C18 
SD 15 
I/O 
D18 
0 V 
GND 
Under normal conditions, the signals -SBHE, LA17 - LA23, -MEMR and MEMW are operated 
as outputs (sending from the CPU). Only CPU modules which are suitable for use as a 
master CPU for system bus access send and receive these signals. A minus sign “-” in front 
of the signal name shows that the signal is LOW active.