Mitsubishi Electronics CR751-D ユーザーズマニュアル
3 Controller
Parallel I/O unit
3-112
Fig.3-35 : Specifications for the connection cable
NETcable-1 (Network cable)
Pin No.
RIO1/2
RIO1/2
Pin No.
1
TXRXH
TXRXH
1
2
TXRXL
TXRXL
2
3
SG(GND)
SG(GND)
3
FG
DCcable-2 (Power cable)
Pin No.
DCIN
1
24V
+
24V Power
2
24G
-
3
FG(PE)
Connected the frame ground or protect ground
R-TM (Terminator)
Pin No.
RIO1/2
100Ω
1
TXRXH
2
TXRXL
3
SG(GND)
List of parts and manufacturer
Type
Connector type
Contact type
Resistant
Manufacturer
NETcable-1
51103-0300 (1)
50351-8100 (3)
-
MOLEX (White connector)
DCcable-2
2-178288-3 (1)
175218-3 (3)
-
Tyco Electronics (Black connector)
R-TM
1-178288-3 (1)
175218-3 (2)
100Ω(1/4W) (1)
Equivalent to KOA.
Note 2)
Note 1)
Note 1) The 24V power supply is prepared by customer (The power consumption is approx. 0.3A.)
In the customer's system, do not ground the + side of 24V power supply prepared by customer for con
-
nect to the controller. (related with emergency stop and parallel input/output) If it connects with the
controller under the condition that the + side is grounded, it will lead to failure of controller.
controller under the condition that the + side is grounded, it will lead to failure of controller.
Note 2) The cable for general purpose can be used to the network cable. However, use the twisted shield cable of
AWG#22(0.3mm
2