Toshiba A1 ユーザーズマニュアル
![Toshiba](https://files.manualsbrain.com/attachments/acaaaa9cc6b763ccfc72ced2ae95d9c94b8b8632/common/fit/150/50/8adbcbcd45c75dc53932fc9caf6f2740daed52d836b76efbd0162ac2599f/brand_logo.png)
2 Troubleshooting Procedures
2.3 Power Supply Troubleshooting
Procedure 2
Error Code Check
If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The
blink pattern indicates an error as shown below.
blink pattern indicates an error as shown below.
Start
Off
for
2
seconds
Error code (8 bit)
“1”
ON
for
one
second
“0”
ON
for
half
second
Interval between data bits
Off
for
half
second
The error code begins with the least significant digit.
Example:
Error code 13h (Error codes are given in hexadecimal format.)
On
Off
Start
1
1
0
0
1
0
0
0
D0
D1
D2
D3
D4
D5
D6
D7
Order
Read
Check 1 Convert the DC IN icon blink pattern into the hexadecimal error code and
compare it to the tables below. Then go to Check 2.
DC power supply (AC adapter)
Error code
Meaning
10h
AC Adapter output voltage is over 16.5V.
11h
Common Dock output voltage is over 16.5V.
12h
Current from the DC power supply is over 6.60A.
13h
Current from the DC power supply is over 0.5A when there is no load.
14h
Abnormal current has been sensed.
2-8