Toshiba A1 ユーザーズマニュアル

ページ / 417
2.6  2.5” HDD Troubleshooting 
2  Troubleshooting Procedures 
Procedure 4 
Diagnostic Test Program Execution Check 
The HDD test program is stored in the Diagnostics Disk. Perform all of the HDD tests in the 
Hard Disk Drive Test. Refer to Chapter 3, Tests and Diagnostics, for more information about 
the HDD test program. 
If an error is detected during the HDD test, an error code and status will be displayed. The 
error codes and statuses are described in Table 2-7. If an error code is not displayed but the 
problem still exists, go to Procedure 5. 
Table 2-7  2.5” Hard disk drive error code and status 
Code Status 
01h Bad 
command 
02h 
Address mark not found 
04h 
Record not found 
05h 
HDC not reset 
07h 
Drive not initialized 
08h 
HDC overrun error (DRQ) 
09h 
DMA boundary error 
0Ah 
Bad sector error 
0Bh 
Bad track error 
10h ECC 
error 
11h ECC 
recover 
enable 
20h HDC 
error 
40h Seek 
error 
80h 
Time out error 
AAh 
Drive not ready 
BBh Undefined 
error 
CCh Write 
fault 
E0h Status 
error 
EEh 
Access time out error 
DAh No 
HDD 
FFh 
Data compare error 
 
Satellite A10/TECRA A1/Satellite Pro A10  Maintenance Manual (960-445) 
2-45