Ethernet CFM Commands
441
Default Configuration
CCMs are not sent by default.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
Example
console(config)#ethernet cfm cc level 1 vlan 15 interval 10
ethernet cfm mep level
Use the ethernet cfm mep level command in Interface Configuration mode 
to create a Maintenance End Point (MEP) on an interface at the specified 
level and direction. MEPs are configured per Maintenance Association per 
Maintenance Domain. Use the no form of the command to delete a MEP.
Syntax
ethernet cfm mep level 
0-7 direction up|down mpid 1-8191 vlan 1-4093
Parameter Description
Default Configuration
No MEPs are preconfigured.
Parameter
Description
level
Maintenance association level
direction 
Up indicates the MEP is facing towards Bridge Relay Entity. 
Down indicates the MEP is facing towards the LAN.
mpid
Maintenance entity identifier
vlan
VLAN on which the MEP operates.