DELL 8132 ユーザーズマニュアル

ページ / 1818
444
Ethernet CFM Commands
ethernet cfm mep archive-hold-time
Use the ethernet cfm mep archive-hold-time command in Interface 
Configuration mode to maintain internal information on a missing MEP. Use 
the no form of the command to return the interval to the default value.
Syntax
ethernet cfm mep archive-hold-time 
hold-time
Parameter Description
Default Configuration
No MEPs are preconfigured.
Command Mode
Interface Configuration
User Guidelines
The hold time should generally be less than the CCM message interval.
Example
The following example sets the hold time for maintaining internal 
information regarding a missing MEP.
console(config)#ethernet cfm mep archive-hold-time 1200
ethernet cfm mip level
Use the ethernet cfm mip level command in Interface Configuration mode 
to create a Maintenance Intermediate Point (MIP) at the specified level. The 
MEPs are configured per Maintenance Domain per interface. Use the no 
form of the command to delete a MIP.
Parameter
Description
hold-time
The time in seconds to maintain the data for a missing MEP 
before removing the data. The default value is 600 seconds.
2CSPC4.X8100-SWUM102.book  Page 444  Friday, March 15, 2013  8:56 AM