DELL 1909 ユーザーズマニュアル

ページ / 62
31
Using Support Tools 
NOTE: To replace parts see the Service 
Manual on the Dell Support website at 
support.dell.com.
One beep — 
BIOS ROM checksum failure.  
Possible motherboard failure
Contact Dell (see “Contacting Dell” on page 44).
Two beeps — 
No RAM Detected
Remove the memory modules, reinstall 
one module and restart the computer. If 
the computer starts normally, reinstall an 
additional module. Continue until you have 
identified a faulty  module or reinstalled all 
modules without an error.
If available, install memory modules of the 
same type in your computer. 
 If the problem persists, contact Dell (see 
“Contacting Dell” on page 44).
Three beeps — 
Possible motherboard failure
Contact Dell (see “Contacting Dell” on page 44).
Four beeps — 
RAM Read/Write failure
Ensure that no special memory module/
memory connector placement requirements 
exist (see the Service Manual on the Dell 
Support website at support.dell.com).
Verify that the memory modules you are 
installing are compatible with your computer.
If the problem persists, contact Dell (see 
“Contacting Dell” on page 44).
Five beeps — 
Real Time Clock Failure
Replace the battery.
System Messages
If your computer has an issue or error, it may 
display a system message that will help you 
identify the cause and action needed to resolve 
the issue.
NOTE: If the message you received is not 
listed in the following examples, see the 
documentation for either the operating 
system or the program that was running