DELL C1100 ユーザーズマニュアル

ページ / 140
About Your System
23
POST Error Codes
Code
Log in BMC Error Message
Corrective Action
0000
Yes
Timer Error
Remove AC power to the system for 
10 seconds and restart the system. 
If the problem persists, see "Getting 
0003
Yes
CMOS Battery Low See "Troubleshooting the System Battery" 
0004
Yes
CMOS Settings 
Wrong
Remove AC power to the system for 
10 seconds and restart the system. 
If the problem persists, see "Getting 
0005
Yes
CMOS Checksum 
Bad
Remove AC power to the system for 
10 seconds and restart the system. 
If the problem persists, see "Getting 
000B
Yes
CMOS memory size 
Wrong
Remove AC power to the system for 
10 seconds and restart the system. 
If the problem persists, see "Getting 
000C
Yes
RAM R/W test failed Remove AC power to the system for 
10 seconds and restart the system. 
If the problem persists, see "Getting 
000E
Yes
A: Driver Error
000F
Yes
B: Driver Error
0012
Yes
CMOS Date/Time 
Not Set
Remove AC power to the system for 
10 seconds and restart the system. See 
book.book  Page 23  Tuesday, February 26, 2013  11:33 AM