HP (Hewlett-Packard) D3J88UT#ABA ユーザーズマニュアル
Using the Computer Setup (F10) Utility to Reset CMOS
1.
Access the Computer Setup (F10) Utility menu.
2.
When the Computer Setup message appears in the lower-right corner of the screen, press
F10
,
and then press
Enter
to bypass the title screen, if necessary.
If you do not press
F10
while the message is displayed, the computer must be rebooted to access
this utility.
3.
From the Computer Setup (F10) Utility menu, select File > Default Setup.
This restores the settings that include boot sequence order and other factory settings. However, it
does not force hardware rediscovery.
4.
Choose Restore Factory Settings as Default, and the press
F10
to accept.
5.
Select File > Apply Defaults and Exit, and then press
F10
to accept.
6.
Reset the computer passwords and configuration information, such as the system date and time.
NOTE:
This step does not clear the passwords.
Clearing and Resetting the CMOS