HP (Hewlett-Packard) 384529-001 ユーザーズマニュアル

ページ / 36
 HP ProLiant DL145 Lights-Out 100i Remote Management User Guide 
 
2.  When POST shows the message 
Press <F10> if you want to 
run BIOS SETUP,
 press the F10 key. If the server has an administrator 
password configured, the system prompts you to enter the password. If the 
server does not have a password configured, the main screen of the BIOS 
Setup Utility appears. 
3.  Press the right arrow (
) key to navigate to the Advanced menu. 
4.  Press the down (
) key to scroll to the Management Processor 
Configuration menu. Press the Enter key. 
5.  Press the down arrow (
) key to scroll to the Serial Port Sharing option. Do 
one of the following: 
− 
Press the + or - key to toggle the setting between Shared and Not Shared. 
Press the Enter key to select the appropriate option. 
− 
Press the Enter key. The Options box appears. Press the up or down 
arrow (
 or 
) key to select Shared with BMC or Not shared W/BMC. 
Press the Enter key to select the appropriate option. 
6. Press 
the 
Esc key to return to the previous screen, or press the F10 key to 
save the changes and exit Setup. 
 
BIOS serial console configuration 
1.  Power on the server by pressing the power on/off button on the front panel. 
2.  When POST shows the message 
Press <F10> if you want to 
run BIOS SETUP,
 press the F10 key. If the server has an administrator 
password configured, the system prompts you to enter the password. If the 
server does not have a password configured, the main screen of the BIOS 
Setup Utility appears. 
3.  Press the right arrow (
) key to navigate to the Advanced menu 
4.  Press the down arrow (
) key to scroll to the BIOS Serial Console 
Configuration menu. Press the Enter key. 
5.  Review the serial port settings and be sure they match the serial port 
communications software settings used to connect to the remote management 
processor.