ENFORCER RACKMOUNT POWER SUPPLY 
 
SECO-LARM U.S.A., Inc.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Parts List: 
Rack mount power supply  ........................................................................................................... 1x 
Cable management brackets  ...................................................................................................... 2x 
Cable management hooks ........................................................................................................... 2x 
M3x6 Cable bracket screws ......................................................................................................... 4x 
Mounting brackets: 
 
16-channel models (rack/wall/surface mount)
 .................................................................................... 2x 
 
32-channel models (wall and surface mount only)
 ............................................................................... 4x 
Extra-long rack mount brackets 
(32-channel models only)
 .................................................................. 2x 
Rubber feet  .................................................................................................................................. 4x 
Power cord  .................................................................................................................................. 1x 
Front panel lock tab 
(Glass Fuse models only) 
 ................................................................................... 1x 
Spare fuses 
(PH-A1612-GUQ only, mounted inside unit, see Installation: Section D)
 ..................................... 3x 
Spare fuses 
(PH-A3224-GUQ only, mounted inside unit, see Installation: Section D)
 ..................................... 6x 
Spare main fuse 
(Mounted inside unit, see Installation: Section C) 
.......................................................... 1x 
Manual  ......................................................................................................................................... 1x 
 
Specifications: 
 
 
PH-A1612-PUQ  PH-A1612-GUQ  PH-A3224-PUQ  PH-A3224-GUQ 
Fuse type 
PTC
1
 
Glass 
PTC
Glass 
Input voltage 
120VAC
2
 
Number of outputs 
16 
32 
Total supply current 
12A@24VAC max. 
10A@28VAC max. 
24A@24VAC max. 
20A@28VAC max. 
Max. amps per ch. 
3A@24VAC max. 
Rack size 
1U 19" (44.5x483 mm) 
Dimensions 
1
3
/
4
"x17
1
/
2
"x11
13
/
32
" (45x445x290 mm) 
Weight 
14-lb 14-oz (6.75kg) 
22-lb 10-oz (10.25kg) 
    
1
Positive Temperature Coefficient 
2
220VAC also available.  Please contact SECO-LARM. 
Installation: 
 
A. Mounting 
1.  Decide on a location to install the unit, away from moisture, high humidity, heat sources, etc. 
2.  Make sure there is enough space around the unit so air can flow in and out for cooling 
purposes. 
3.  Be sure ventilation holes are not blocked by other equipment, rack housing, walls, etc. 
4.  To avoid undesirable operation in either the product or other equipment place the unit at 
least 12” (30cm) from any television monitor or other radiation-producing, radiation-sensitive 
or heat-producing equipment such as heaters, radiators, etc. 
A1. Shelf/table mounting 
1.  Units may be stacked one on top of the other, or with other equipment. 
2.  Make sure the rubber feet are firmly attached to the bottom of the unit as shown in Figure 10 
in the Overview section on page 7, and that no ventilation holes are blocked.