REG_ADCLO (base+0Ah): ADC command, status, and result low byte (read/write) 
Writing to this register starts a new A/D conversion.  You should only do this 
when the ADC is idle. 
Command bits: 0000
dccc 
  
d: 0:single-ended, 1=differential 
  
ccc: Channel. 
  
d  c  c  c  Conversion 
0  0  0  0  AIN0 relative to AGND 
0  0  0  1  AIN1 relative to AGND 
0  0  1  0  AIN2 relative to AGND 
0  0  1  1  AIN3 relative to AGND 
0  1  0  0  AIN4 relative to AGND 
0  1  0  1  AIN5 relative to AGND 
0  1  1  0  AIN6 relative to AGND 
0  1  1  1  AIN7 relative to AGND 
1  0  0  0  Differential AIN0(+) - AIN1(-) 
1  0  0  1  Differential AIN1(-) - AIN0(+) 
1  0  1  0  Differential AIN2(+) - AIN3(-) 
1  0  1  1  Differential AIN3(-) - AIN2(+) 
1  1  0  0  Differential AIN4(+) - AIN5(-) 
1  1  0  1  Differential AIN5(-) - AIN4(+) 
1  1  1  0  Differential AIN6(+) - AIN7(-) 
1  1  1  1  Differential AIN7(-) - AIN6(+) 
 
Reading REG_ADCLO returns status and result bits. 
Result bits: 
rrrr00pb 
  
p: ADC present.  If 1, the ADC is available.  If 0, the ADC is not mounted, and 
     you should not write to REG_ADCLO. 
  
b: Busy. 0 = ADC idle. The previous result can be read, and a new conversion can 
     be started.  1 = conversion in progress.  All result bits are invalid when 
b=1. 
  
rrrr: Four least-significant bits of the conversion result.  Only valid when b=0. 
 
REG_ADCHI (base+0Bh): ADC result, high byte (read only) 
Reading this register returns the eight most-significant bits of the conversion 
result.  Only valid when the ADC is idle.