Whistler PRO-1200W ユーザーズマニュアル

ページ / 17
TROUBLESHOOTING
25
PROBLEM:  TV Interference
Problem
Solution
Electrical interference from
Add a Ferrite data line
filter inverter.
on to the TV power cord.
This filter is available at 
electronic supply stores. 
PROBLEM:  Low or No Output Voltage
Problem
Solution
Using incorrect type of
Use true RMS reading meter
voltmeter to test output
See "For You Technical 
voltage.
Types" Section of this 
manual.
PROBLEM:  Low Battery Alarm On All The Time
Problem
Solution
Input voltage below 
Keep input voltage above 
11 volts.
11 volts to maintain 
regulation.
Poor or weak battery 
Replace battery.
condition.
Inadequate power being
Use lower gauge wire. See 
delivered to the inverter
“Wire Cable Gauges”
or excessive voltage drop.
section of this manual.  
Keep wire length as short 
as possible.
24
TROUBLESHOOTING
Overload  LED on
Problem
Solution
Equipment has a high
Turn inverter power switch
start up surge.
OFF (O) and then ON (l) 
again until the inverter 
powers your appliance.  
Repeat as necessary
to get your appliance 
"started".
Battery voltage below 
Recharge or replace 
10 volts.
battery.
Equipment being operated
Use a higher capacity 
draws too much power.
inverter.
Inverter is too hot (thermal
Allow inverter to cool.
shutdown mode).
Check for adequate 
ventilation.  Reduce the 
load on the inverter to
rated continuous power
output.
pro1200to3000w.qxp  4/30/2010  8:55 AM  Page 27