Allied Telesis AT-WDRPS-10 プリント

ページ / 2
4.
Secure the AT-WDRPS-10 unit to the AT-WD1008 chassis by tightening the two 
thumbscrews.
Note
If you are installing the AT-WD1008 Multiplexer for the first time, refer to the 
AT-WD1008 Installation Guide for instructions on how to complete the 
installation.  
5.
Connect the power cord to the RPS AC power connector, located in the back of 
the multiplexer, and the other end of the cord to an appropriate AC power 
source.
6.
 Turn the RPS power switch to the ON position.
7.
Check that the POWER LED on the front of the RPS module is green.  If the 
POWER LED is OFF or the FAULT LED is ON, refer to the AT-WD1008 Installation 
Guide 
 for troubleshooting instructions.
Note
For added power protection to the multiplexer, the two AC power cords 
should be connected to power sources that are operating from different 
power circuits. This will protect the multiplexer from a power loss should one 
of the power circuits fail.
This completes the installation procedure for the AT-WDRPS-10 unit. 
LNK TST
TX
RX
LNK TST
TX
RX
EAST
TX
SNMP M
ODULE
ST
TX
RX
RX
TX
CH 5
TX
RX
RX
TX
CH 6
TX
RX
RX
TX
CH 7
TX
RX
RX
TX
CH 8
TX
RX
FAN A
FAN B
POWER
SUPPLY
 B
WEST
EAST
NORMA
L
LNK TST
POWER
FAULT
AT-WDR
PS-10
AT-WDFAN01
Power ON/OFF
Switch for
AC Power Inlet
the Optional
RPS Module
for the Optional
RPS Module
AC Power Inlet
for the Standard
Power Module
Power ON/OFF
Switch for
the Standard
Power Module
Technical Specifications
Electrical Rating
Input Voltage
100 - 240 V AC, 3.2A maximum
AC Input Frequency:
47-63 Hz
Power Comsumption
75 watts maximum
Environment
Operating Temperature:
0° C to 40° C (32° F to 104° F)
Storage Temperature:
-25° C to 70° C (-13° F to 158° F) 
Operating Relative Humidity:
5% to 90% RH (non-condensing)
Storage Relative Humidity:
5% to 95% RH (non-condensing)
Operating Altitude Range:
Up to 3,000 m (9,843 ft)
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
Emission
FCC Class A, EN55022 Class A, VCCI Class A, EN6100-3-2, EN6100-3-3
WARNING
In a domestic environment this product may cause radio interference in which case the user may be 
required to take adequate measures. 
Immunity
EN55024
Electrical Safety UL60950 (cULus), EN60950 (TUV)
Copyright 
 2003 Allied Telesyn, Inc. All rights reserved. 
No part of this publication may be reproduced without prior written permission from Allied Telesyn Inc.
U.S. Federal Communications Commission 
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to 
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to 
operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du 
Canada.