_______________________________________________________________________________________APPLICATIONS 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Two Identical Negative Voltages With a Common 
Positive (Refer To Fig. 13) 
 
When the same negative voltage is required at two points 
in the same circuit and a common positive is needed, 
perform the following: 
 
1. Select the TRACKING PARALLEL operating mode 
and set the A/B Metering switch to monitor the “A” 
supply. 
2. Set the desired voltage and maximum current using the 
“A” VOLTAGE and CURRENT controls. 
3. Connect a ground wire between the “A” supply positive 
terminal and the GND (green) terminal. 
4. Turn off the power supply and the equipment to be 
powered during hook-up. 
5. Connect the negative polarity inputs of the circuit to be 
powered to the negative (black) terminals of the 
supplies. Connect the common positive input of the 
circuit to be powered to the “A” supply’s positive (red) 
or GND (green) terminal. 
 
 
Fig. 13. Typical Hook-Up Using Two Identical 
Negative Voltages and a Common Positive.