Lamp Replacement Procedure:
.  Switch off the power to the projector by pressing the “ ” button. 
2.  Allow the projector to cool down for at least 30 minutes.
3.  Disconnect the power cord.
4.  Unscrew the two screws on the cover. 
5.  Lift up and remove the cover. 2
6.  Unscrew the two screws on the lamp module. 3
7.  Lift up the lamp handle and remove the lamp module slowly and carefully. 4
To replace the lamp module, reverse the previous steps.
8.   Turn on the projector and use “Lamp Reset” after the lamp module is 
replaced.
Lamp Reset: (i) Press “Menu”  (ii) Select “OPTIONS”  (iii) Select 
“Lamp Settings”  (iv) Select “Lamp Reset”  (v) Select “Yes”.
1
2
3
4
The screws on the 
lamp cover and the 
lamp cannot be 
removed. 
 
The projector 
cannot be turned 
on if the lamp 
cover has not been 
placed back on the 
projector. 
 
Do not touch the 
glass area of the 
lamp. Hand oil can 
cause the lamp to 
shatter. Use a dry 
cloth to clean the 
lamp module if it 
was accidentally 
touched.