Indicators
This projector has two indicators, each of which shows the operation condition of the projector. 
The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your dealer.
Normal condition
Abnormal condition
POWER
STATUS
CONDITION
NOTE
Stand-by
Power up process (About 4 seconds)
The power is on. (Normal condition)
Lamp cooling down. (About 90 seconds)
Lamp lit up (About 60 seconds)
STATUS indicator
POWER indicator
Steady red
Off
Blinking red
Off
Steady green
Steady green
Steady green
Blinking  green
POWER
STATUS
CONDITION
POSSIBLE SOLUTION
Lamp failure
Replace the lamp and reset the lamp hour.
Color wheel failure
Contact your dealer.
Fan failure
Check if the fan is clogged with dust or dirt and 
clean it.
If the above solution is not effective, contact your 
dealer.
Abnormal temperature
Clean the ventilation grilles.
Relocate the projector to a cooler place.
For the directly shut down, it will check the 
temperature first, if it's too high, it will start 
cooling for 90 seconds. 
If it's abnormal shut down in the previous time,  
while the temperature is too high, it will start the 
cooling process after 90 seconds when the 
temperature is still too high.
95% Lamp life exceed
Replace the lamp and reset the lamp hour.
Lamp life end
Replace the lamp and reset the lamp hour.
Lamp cover open
Put back the lamp cover.
Off
Blinking green about 
30 seconds after 
power on.
Steady green
   Steady amber 
about 5 seconds after 
power on.
Blinking green
Steady green about 
20 seconds after 
power on.
Steady green
Steady red about 10 
seconds after power 
on.
Steady green
Blinking red
Off
Steady red about 5 
seconds after power 
on.
N/A