Indicators
This projector has 2 indicators, each of which shows the operation condition of the projector. 
The following offer solutions to possible problems. If these problems persist, turn the projector off and consult your 
dealer. 
POWER indicator 
STATUS indicator
Normal condition
POWER
STATUS
CONDITION
NOTE
Steady
red
Off
Stand-by
Blinking
green
Lamp stand-by for power-off
The power cannot be turned on by pressing 
the POWER button.
Steady
green
Blinking
green
Lamp stand-by for power-on
The power cannot be turned off by pressing 
the POWER button.
Steady
green
The power is on. (Normal condition)
Abnormal condition
POWER
STATUS
CONDITION
POSSIBLE SOLUTION
Steady 
green
or
Steady 
red
Blinking orange
Abnormal temperature
•  The ventilation grilles are clogged with dust or dirt.
•  The room temperature is high.
•  Clean the ventilation grilles.
•  Relocate the projector to a cooler place.
Steady 
red
Blinking green
The protection circuit is working or the lamp is in an 
abnormal condition.
•  Wait until the STATUS indicator goes out,
then press the POWER button.
•  If the above solution is not effective,
replace the lamp.
Steady 
green
Blinking green/red
Lamp operation time warning. (Total lamp operation 
time reached 3000 hours
*1
 while the power was on.)
Replace the lamp.
Change with a new lamp if this problem 
recurs.
Steady 
red
Blinking red
Lamp operation time warning. (Total lamp operation 
time reached 3000 hours
*1
 while the power was off.)
Steady red
Lamp operation time warning. (Total lamp operation 
time reached 4000 hours
*1*2
 while the power was off.)
Blinking 
green/red
Steady 
or 
 
Blinking
Abnormal.
Contact your dealer.
*1: Duration when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be 
shorted.