Mitsubishi Electronics UD8850U ユーザーズマニュアル
11
[Example] When displaying the MENU selection bar. (Values enclosed in quotation marks are ASCII codes.):
•
•
Command sent from the PC, etc.
Status code returned
from the projector
Description
‘30’ ‘30’ ‘72’ ‘35’ ‘34’ ‘0D’
00r54
00r54
Command operating the same as
the MENU button (ID command is
omitted.)
the MENU button (ID command is
omitted.)
‘30’ ‘30’ ‘72’ ‘35’ ‘34’ ‘0D’
00r54
00r54
Command receipt confirmation (The
statuses are echoed back as many
as the number of the connected
projectors.)
statuses are echoed back as many
as the number of the connected
projectors.)
•
Command sent from the PC, etc.
Status code returned
from the projector
Description
‘30’ ‘30’ ‘3B’ ‘30’ ‘31’ ‘3B’ ‘72’ ‘35’ ‘34’ ‘0D’
00;01;r54
00;01;r54
Command operating the same as the
MENU button is sent to the projector
with the ID of “01” or “ALL.”
MENU button is sent to the projector
with the ID of “01” or “ALL.”
‘30’ ‘30’ ‘3B’ ‘30’ ‘31’ ‘3B’ ‘72’ ‘35’ ‘34’ ‘0D’
00;01;r54
00;01;r54
Command receipt confirmation
(The status is echoed back from the
projector with the ID of “01” or “ALL.”)
(The status is echoed back from the
projector with the ID of “01” or “ALL.”)
5.4 Direct commands
(Not executable in stand-by mode. Possible only to read during BLANK.)
The direct commands are used to numerically adjust the geometrical correction and bright uniformity correction.
When the computer sends the command without adding the setting value, the projector returns the received
command with the current setting value added as a data code.
When the computer sends the command without adding the setting value, the projector returns the received
command with the current setting value added as a data code.
ITEM
Function
Data
Character
ASCII code
KEYSTONE (vertical)
KS
4Bh 53h
±40
With CURVED-adjustment : ±10
With CURVED-adjustment : ±10
KEYSTONE (horizontal)
KSH
4Bh 53h 48h
±25
With CURVED-adjustment : ±10
With CURVED-adjustment : ±10
KEYSTONE reset
KSRST
4Bh 53h 52h 53h 54h
CORNERSTONE LOWER RIGHT (vertical)
CNLRV
43h 4Eh 4Ch 52h 56h
±99
CORNERSTONE LOWER RIGHT (horizontal)
CNLRH
43h 4Eh 4Ch 52h 48h
±99
CORNERSTONE LOWER LEFT (vertical)
CNLLV
43h 4Eh 4Ch 52h 56h
±99
CORNERSTONE LOWER LEFT (horizontal)
CNLLH
43h 4Eh 4Ch 52h 48h
±99
CORNERSTONE UPPER RIGHT (vertical)
CNURV
43h 4Eh 55h 52h 56h
±99
CORNERSTONE UPPER RIGHT (horizontal)
CNURH
43h 4Eh 55h 52h 48h
±99
CORNERSTONE UPPER LEFT (vertical)
CNULV
43h 4Eh 55h 52h 56h
±99
CORNERSTONE UPPER LEFT (horizontal)
CNULH
43h 4Eh 55h 52h 48h
±99
CORNERSTONE reset
CKSRST
43h 4Bh 53h 52h 53h 54h
HORIZ. CURVED ARC
CVAH
43h 56h 41h 48h
±99
With KEYSTONE- or
CORNERSTONE-adjustment
: ±30
With KEYSTONE- or
CORNERSTONE-adjustment
: ±30
VERT. CURVED ARC
CVAV
43h 56h 41h 56h
±99
With KEYSTONE- or
CORNERSTONE-adjustment
: ±30
With KEYSTONE- or
CORNERSTONE-adjustment
: ±30
HORIZ. CURVED ORIGIN (vertical)
CVHOV
43h 56h 48h 4Fh 56h
±10
HORIZ. CURVED ORIGIN (horizontal)
CVHOH
43h 56h 48h 4Fh 48h
±10
VERT. CURVED ORIGIN (vertical)
CVVOV
43h 56h 56h 4Fh 56h
±10
VERT. CURVED ORIGIN (horizontal)
CVVOH
43h 56h 56h 4Fh 48h
±10
CURVED reset
CVRST
43h 56h 52h 53h 54h
BRIGHT UNIFORMITY CORRECTION (level)
BUCL
42h 55h 43h 4Ch
050 to 100
(Changeable in five increments)
BRIGHT UNIFORMITY CORRECTION
(correcting position) (vertical)
(correcting position) (vertical)
BUCV
42h 55h 43h 56h
1 to 7
BRIGHT UNIFORMITY CORRECTION
(correcting position) (horizontal)
(correcting position) (horizontal)
BUCH
42h 55h 43h 48h
1 to 7
How to set the value
Use the character or ASCII code as shown below to set the value.
Use the character or ASCII code as shown below to set the value.
Character
+
-
0
1
2
3
4
5
6
7
8
9
ASCII code ‘2Bh’ ‘2Dh’ ‘30h’ ‘31h’ ‘32h’ ‘33h’ ‘34h’ ‘35h’ ‘36h’ ‘37h’ ‘38h’ ‘39h’