ICP DAS USA MSM-508FCS ユーザーズマニュアル

ページ / 27
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual   
 
April 29, 2008 
 
24 
 
 
 Default Setting 
This function allows you to clean all settings and load the default value to Switch Management. 
 
Current factory default values are
 
Network Setting 
IP Address 
: 192.168.255.1   
Gateway   
: 192.168.0.1 
Mask  
 
: 255.255.0.0 
Modbus Net ID 
: 1
 
 
Serial Port Setting 
COM1 
:baudrate 115200,8bit,none patity check, 1 stopbit 
COM2 
:baudrate 115200,8bit,none patity check, 1 stopbit 
 
Redundant Setting 
Ring Pair 1 
: disabled 
Ring Pair 2 
: disabled 
Protocol   
: Cyber-Ring Protocol 
Ring Coupling  : Primary Switch 
Recovery Time  : 300ms 
 
 
 Reboot Setting 
When you finish the Network Setting, you have to reboot the Switch to activate the value, you 
can restart the system by clicking following reboot icon.