Cabletron Systems 9F206-02 ユーザーズマニュアル

ページ / 10
 
1
 
Appendix
 
9F206-02 Module
Specific Information
 
Introduction
 
This appendix contains local management information that is speciÞc to the 
9F206-02 FDDI Repeater Module.
The 9F206-02 FDDI Repeater Module physically attaches to the FNB-1 and the 
FNB-2 on the SmartSwitch 9000Õs FNB backplane. By default, the module inserts 
into four rings (the primary and secondary rings of the FNB-1 and the FNB-2). 
The 9F206-02 ConÞguration Screen allows you to customize this conÞguration to 
your particular needs. The default values that appear on this screen are 
determined by the moduleÕs DIP switches. (For more information on setting this 
moduleÕs DIP switches, refer to the 
 
SmartSwitch 9000 9F206-02 FDDI Repeater 
MicroLAN Module UserÕs Guide
 
.)
The 9F206-02 ConÞguration Screen allows you to:
¥
Establish whether the moduleÕs two FDDI-1 front panel connections will insert 
into the backplaneÕs FNB-1 (primary and secondary) rings or bypass the FNB-1 
rings (see Figure 1).
¥
Establish whether the moduleÕs two FDDI-2 front panel connections will insert 
into the backplaneÕs FNB-2 (primary and secondary) rings or bypass the FNB-2 
rings (see Figure 1).
The terms ÒInsertedÓ and ÒBypassedÓ refer to relays that are located on the 
module. Inserted causes a relay to connect the moduleÕs speciÞc front panel 
connections to the selected ring. Bypassed causes a relay to disconnect the 
moduleÕs speciÞc front panel connections from the selected ring.