Enter the 
ip rip stats
 administration console command. Look for the IfStatRcvResponses 
counter for the interface. This statistics is the number of RIP update messages received on the 
interface.
If the total number of these counters is 0, check the Router to verify that it is configured to send 
IP RIP update messages.
3.
Also look for the IfStatRcvBadPackets and IfStatRcvBadRoutes counters.
If these counters are not 0, there may be something wrong with the Router.
If these counters are 0, there is an unexpected condition present within the CyberSWITCH 
system software. Contact customer support.
IPX R
OUTING
This section provides methods for diagnosing problems in the following areas of IPX routing:
IPX R
OUTING
 I
NITIALIZATION
Problem:
The CyberSWITCH does not display the correct IPX Initialization messages. Instead, it displays the 
following message (display messages by entering the 
dr
 console command):
 [IPX] Initialization failure
Action:
An internal error has occurred. Contact Customer Support
.
IPX R
OUTING
 
OVER
 
THE
 LAN C
ONNECTION
Problem:
The CyberSWITCH does not display the correct message after issuing the 
ipx diag
 or 
ipx ping
 
command. Instead, it displays the following message:
No response from <ipx-address>
Action:
1.
Verify that the routing entry for the destination network exists by entering the following 
console command:
ipx route
If the CyberSWITCH displays the route to the destination, it knows how to reach the local 
server’s internal network. Determine if this is a static route or a dynamic route learned via RIP. 
The output of an 
ipx route
 command contains a protocol (P) field for each route entry, which