Cabletron Systems 9A000 ユーザーズマニュアル
B-5
SCP Diagnostics
B.1.2.3
DRAM Chip Test
This test checks the functionality of a DRAM chip. It takes about two seconds
to run.
to run.
=>test-dc a
DRAM chip: OK
B.1.2.4
Ethernet Test
This test checks the functionality of the Ethernet chip. It takes about two sec-
onds to run.
onds to run.
=>
test-ethernet
Ethernet: OK
B.1.2.5
FLASH Test
This test checks the functionality of each FLASH chip. It takes about five min-
utes to run.
utes to run.
NOTE:
It is recommended that you back up your
CDB before running this test. The chips are
saved before testing each one and then
restored. However, if a power failure would
occur or if the switch were rebooted during
the test, some of the data may not be restored
properly.
CDB before running this test. The chips are
saved before testing each one and then
restored. However, if a power failure would
occur or if the switch were rebooted during
the test, some of the data may not be restored
properly.
=>
test-flash
Flash Test
Save Chip 0
Erase Chip
Pattern 0
Erase Chip
Pattern 1
Erase Chip
Pattern 2
Erase Chip
Pattern 3
.