Switch Setup
4.6.1
Installing the SFCS-1000
To install the SFCS-1000 in the equipment rack, use the following procedure:
1.
Choose a rack position for the SFCS-1000.
WARNING!
Because of the unit’s weight, two people
should lift the unit to place it in the equipment
rack.
2.
Place the SFCS-1000 in the rack with the front of the unit facing
forward.
CAUTION
When it is mounted in the equipment rack, do
not use the SFCS-1000 chassis to support other
equipment. This could overload the mounting
brackets and cause damage to the unit.
3.
After mounting the enclosure, verify that the enclosure is screwed
tightly to the rack to ensure that proper grounding is maintained.
Additionally, the rack should be connected to an earth ground.
NOTE:
The SFCS-1000 is an operational ATM switch
at this point if used with other Cabletron
switches or with ATM interface cards. How-
ever, if other vendor equipment is connected,
you may have to complete an initial user con-
figuration.
NOTE:
If you wish to have remote access to the
switch, you must first install a serial cable
and configure a modem. Please refer to sub-
sections 4.7 and 4.8 for more information.