Cabletron Systems SFCS-200WG ユーザーズマニュアル

ページ / 180
A-6
Troubleshooting
A.1.5 Check Firmware
To check whether or not the firmware is running correctly, issue the following
command:
atmstat fa0 1
In this command, the last parameter “1”, causes the command to be repeated
at one-second intervals.
If the firmware is running correctly, the response will show Input, Output,
and Error Statistics for the adapter in the following format:
  
  PHY/ATM/AAL statistics:
  
       Output               Input                       Errors
  
     ATM     AAL*        ATM     AAL*    4B5B    4B5B     ATM    AAL*    AAL*
   
   Cells  CS-PDUs      Cells  CS-PDUs Framing Hdr-CRC VPI/VCI Pay-CRC   Proto
  
  161747   153692     142289   134685       0       0      20       0       0
If the firmware is not running correctly, atmstat hangs and nothing is
returned, indicating either a problem with the firmware, a problem with the
board, or a severe software failure. Call Cabletron Systems’ Technical Support
for further assistance.
If the output shows zeros for all possible values, the firmware may not have
been initialized. Try rebooting the system. If there is still a problem, call
Cabletron Systems’ Technical Support for further assistance.