Cisco Systems 11500 Series ユーザーズマニュアル

ページ / 184
2-39
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-06
Chapter 2      Cabling and Troubleshooting the CSS
Troubleshooting the CSS Hardware Components
Troubleshooting the CSS Modules
CSS 11503 and CSS 11506 module status is indicated by the Status LED on the 
module front panel. For information about the module LEDs, see the 
 section earlier in this chapter.
 provides suggestions for correcting problems that may occur with the 
modules in the CSS 11503 and CSS 11506. 
Caution
Always power down the CSS prior to removing or installing a module.
Note
As implemented in WebNS 5.10 and greater, when a CSS module fails during 
normal operations, the CSS reboots.
Table 2-12 Troubleshooting the CSS Modules
Symptom
Recommended Action
At boot up, the following 
message appears:
CHMGR: Slot 
slot
/
subslot
 
had diagnostic failures - 
NOT STARTING UP
1.
Power down the CSS.
2.
Reseat the module in its slot.
3.
Power up the CSS to boot the module.
If reseating the module does not correct the 
failure, replace the module. Refer to the 
reference sheet that comes with the 
replacement module.
During normal CSS operation, 
the following message appears 
and then, the CSS reboots:
ONDM: LifeTick for 
Sub-Module in slot/sub-slot 
slot
/
subslot
 failed, 
resetting..
If the module is not functioning, the left Status 
LED will be Red and blinking slowly. If it is an 
FEM, all of its Link and Duplex LEDs will 
blink synchronously. When the CSS reboots, 
the Status LED is off. Use the show chassis 
command to verify the state of the module.
1.
Replace the module. Refer to the reference 
sheet that comes with the replacement 
module.
2.
Power up the CSS to boot the module.