Philips BUK216-50YT ユーザーズマニュアル

ページ / 8
Philips Semiconductors
Product specification
 TOPFET high side switch
BUK216-50YT 
 SMD version
 
OVERLOAD PROTECTION / DETECTION CHARACTERISTICS
6 V 
 V
BG
 
 35 V, limits are at -40˚C 
 T
mb
 
 150˚C and typicals at T
mb
 = 25 ˚C unless otherwise stated.
Refer to 
TRUTH TABLE
.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
Overload protection
V
BL
 = V
BG
I
L(lim)
Load current limiting
V
BG
 
 9 V
10
15
21
A
Short circuit load detection
Status indication only
V
BL(TO)
Battery load threshold voltage
1
V
BG
 = 16 V
8
10
12
V
V
BG
 = 35 V
15
20
25
V
Overtemperature protection
T
j(TO)
Threshold junction
150
170
190
˚C
temperature
2
SWITCHING CHARACTERISTICS
T
mb
 = 25 ˚C, V
BG
 = 13 V, for resistive load R
L
 = 13 
Ω
.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
During turn-on
from input going high
t
d on
Delay time
to 10% V
L
-
40
60
µ
s
dV/dt
on
Rate of rise of load voltage
30% to 70% V
L
-
0.5
1
V/
µ
s
on
Total switching time
to 90% V
L
-
160
225
µ
s
During turn-off
3
from input going low
t
d off
Delay time
to 90% V
L
-
70
100
µ
s
dV/dt
off
Rate of fall of load voltage
70% to 30% V
L
-
0.5
1
V/
µ
s
off
Total switching time
to 10% V
L
-
95
130
µ
s
CAPACITANCES
T
mb
 = 25 ˚C; f = 1 MHz; V
IG
 = 0 V.  designed in parameters.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
C
ig
Input capacitance
V
BG
 = 13 V
-
15
20
pF
C
bl
Output capacitance
V
BL
 = 13 V
-
425
600
pF
C
sg
Status capacitance
V
SG
 = 5 V
-
11
15
pF
The battery to load threshold voltage for short circuit detection is proportional to the battery supply voltage.
Latched protection.  After cooling below the threshold temperature the switch will resume normal operation only after the input has been
toggled low.
For measurement purposes an Input pulse of 1.5ms is used to ensure the device is stabilised in the on state.
March 2002
6
Rev 1.200