Patton electronic 2156 & 2157 ユーザーズマニュアル

ページ / 20
 
11
 
External 48 VDC power supply
 
• Input 
 
Rated voltage: 36–60 VDC
 
 
Rated current: 0.25 A DC at nominal 48 VDC
 
 
3-pin locking connector, 3.5 mm pitch
 
 
Reverse polarity protection
 
 
Transient over-voltage protection, 100 VDC at 2 ms
 
• Output
 
Rated voltage: 5 VDC ± 5%, 5W
 
 
Rated current; 1 A DC
 
 
6-inch cable terminated with 2.5 mm barrel plug, center positive
 
Caution
 
An approved LPS external power supply that incorporates 
a disconnect device must be used and positioned within 
easy reach of the operator’s position.
 
Caution
 
Connect the equipment to a 5 VDC source that is electri-
cally isolated from the AC source. The 5 VDC source is to 
be reliably connected to earth.
 
Caution
 
An approved LPS external power supply that incorporates 
a disconnect device must be used and positioned within 
easy reach of the operator’s position.
 
Caution
 
Connect the equipment to a 36–60 VDC source that is 
electrically isolated from the AC source. The 36–60 VDC 
source is to be reliably connected to earth.