Patton electronic 2156 & 2157 ユーザーズマニュアル
11
External 48 VDC power supply
• Input
–
Rated voltage: 36–60 VDC
–
Rated current: 0.25 A DC at nominal 48 VDC
–
3-pin locking connector, 3.5 mm pitch
–
Reverse polarity protection
–
Transient over-voltage protection, 100 VDC at 2 ms
• Output
–
Rated voltage: 5 VDC ± 5%, 5W
–
Rated current; 1 A DC
–
6-inch cable terminated with 2.5 mm barrel plug, center positive
Caution
An approved LPS external power supply that incorporates
a disconnect device must be used and positioned within
easy reach of the operator’s position.
a disconnect device must be used and positioned within
easy reach of the operator’s position.
Caution
Connect the equipment to a 5 VDC source that is electri-
cally isolated from the AC source. The 5 VDC source is to
be reliably connected to earth.
cally isolated from the AC source. The 5 VDC source is to
be reliably connected to earth.
Caution
An approved LPS external power supply that incorporates
a disconnect device must be used and positioned within
easy reach of the operator’s position.
a disconnect device must be used and positioned within
easy reach of the operator’s position.
Caution
Connect the equipment to a 36–60 VDC source that is
electrically isolated from the AC source. The 36–60 VDC
source is to be reliably connected to earth.
electrically isolated from the AC source. The 36–60 VDC
source is to be reliably connected to earth.