5 • Troubleshooting and maintenance
Model 6511RC User Manual
94
Periodic maintenance
Note
Path-1 trace message is used for 16-byte and 64-byte path-1 trace 
messagesFor 1-byte and 64-byte trace messages, the J1 byte is used 
and the value of path-1trace message is ignored.
5. For Path-1 Trace Msg Len, select the value corresponding to the trace message length your connected SDH 
network uses.
6. For Path-1 Trace J1 Byte, enter the value your connected SDH network uses for the J1 byte in the 
SDH frame.
Note
J1 is used only for 1-byte path trace messages. For 16-byte and 64-
byte trace messages, the trace message string is used and the value of 
J1 is ignored.
7. For Path-1 Signal Label, enter the value your connected SDH network uses for the path-1 signal label in 
the SDH frame.
8. If you have selected AU-3 mapping, repeat steps 3 through 7 to define values for the Path-2 and Path-3 
trace parameters.
9. Click the Submit button to save your work into operating memory (volatile DRAM) and activate the new 
parameter values.
Periodic maintenance
Consult the rack chassis user manual for information on preventative maintenance (such as cleaning the chassis 
air cooling vents to remove accumulated dust).
Calibration
The Model 6511RC requires no calibration.
Maintenance
This section describes replacing the Model 6511RC.
Replacing the Model 6511RC
If you isolate a problem to the a Model 6511RC component, the entire Model 6511RC must be replaced 
as described in the follow section.
Exporting the current Model 6511RC configuration
The 6511RC Matrix Switch provides Import/Export functions. These functions enable you to back up (export) 
and restore (import) your Matrix Switch’s configuration parameters against possible failure. Should your 
Matrix Switch ever need replacing, a previously saved copy of your (exported) configuration file can quickly be 
loaded (imported) into a replacement Matrix Switch.
Note
Import/Export functions require superuser access privileges.