D-Link DES-3250TG ユーザーズマニュアル

ページ / 186
D-Link DES-3250TG Standalone Layer 2 Switch
 
 
 
Figure 9- 14.  Rx Size Analysis window (table) 
The following fields can be set: 
Parameter 
               Description 
Time Interval [1s ] 
Select the desired setting between 1s and 60s
where “s” stands for seconds. The default 
value is one second. 
Record Number [200
Select number of times the Switch will be 
polled between 20 and 200. The default value 
is 20. 
64 
The total number of packets (including bad 
packets) received that were 64 octets in 
length (excluding framing bits but including 
FCS octets). 
65-127 
The total number of packets (including bad 
packets) received that were between 65 and 
127 octets in length inclusive (excluding 
framing bits but including FCS octets). 
128-255 
The total number of packets (including bad 
packets) received that were between 128 and 
255 octets in length inclusive (excluding 
framing bits but including FCS octets). 
256-511 
The total number of packets (including bad 
packets) received that were between 256 and 
511 octets in length inclusive (excluding 
136