5 – Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
59096-04  A
5-9
A
4.
Compare the RA_TOV and ED_TOV timeout values for all switches in the 
fabric using the Show Config Switch command. Is each timeout value the 
same on every switch?
„
Yes - Continue.
„
No - Correct the timeout values on the offending switches using the 
Set Config Switch CLI. Reset the port. If the condition remains, 
continue.
5.
Display the active zone set on each switch using the Zoning Active 
command. Compare the zone membership between the two active zone 
sets. Are they the same?
„
Yes - Contact your authorized maintenance provider.
„
No - Deactivate one of the active zone sets or edit the conflicting zones 
so that their membership is the same. Reset the port. If the condition 
remains, contact your authorized maintenance provider.
5.2.2.2
Excessive Port Errors
The switch can monitor a set of port errors and generates alarms based on 
user-defined sample windows and thresholds. These port errors include the 
following:
„
CRC errors
„
Decode errors
„
ISL connection count
„
Device login errors
„
Device logout errors
„
Loss-of-signal errors
Port threshold alarm monitoring is disabled by default. Refer to the SANbox 5000 
Series Fibre Channel Switch Command Line Interface Guide
 for information about 
managing port threshold alarms.
                                                                                           
NOTE:
This can be caused by merging two fabrics whose active 
zone sets have two zones with the same name, but 
different membership.