Chapter 4 – Configuring VLANs 
PVID (Native VLAN)  
The Port VLAN Identifier (PVID) or native VLAN specifies the VLAN id 
associated with untagged (and 802.1p priority tagged) frames received on this port. 
Note:
 If the VLAN configured as the PVID does not exist in the “Configure VLANs” 
menu, the switch will automatically create and use it.  IGMP will automatically be disabled for 
that VLAN.  If it is desirable for IGMP to be used on that VLAN, it can be created in the 
“Configure VLANs” menu and IGMP enabled. 
PVID Format 
This parameter specifies whether frames transmitted on the native VLAN are to be 
sent tagged or untagged. 
VLAN Summary Menu  
The VLAN Summary menu is accessible from the Virtual LANs menu.  This menu 
presents configured VLANs and the ports they are available upon.  Ports that are 
untagged or tagged members of the VLAN are shown under the appropriate 
“Untagged Ports” or “Tagged Ports” column.  The management VLAN (VLAN 1) 
is always shown. 
Figure 23: VLAN Summary Menu 
 
My Switch                VLAN Summary                               Admin Access 
 
                     VID  Untagged Ports Tagged Ports 
                     1    1-12, 15-16    13-14 
                     2    None           1-2, 5, 7 
                     3    3, 8-12        None 
                     4    4, 15-16       None 
 
 