3com 5500G ユーザーズマニュアル

ページ / 336
1
L
OGIN
 C
ONFIGURATION
 G
UIDE
n
Unless otherwise specified, all the switches used in the following configuration 
examples and configuration procedures are Switch 5500 (release V03.02.04).
Logging In from the 
Console Port
You can log in locally from the console port to configure and maintain your switch, 
including configuring other login modes. The default login mode on the Switch 
5500 is local console login.
Network Diagram
Figure 1   Logging in from the console port to configure Telnet login
 
Networking and
Configuration
Requirements
As shown in Figure 1, use a console cable to connect the serial port of your 
PC/terminal to the console port of the switch. Log into the switch from the AUX 
user interface on the console port to configure Telnet login. The current user level 
is manage level (level 3).
Applicable Products
Configuration Procedure
Configure common attributes for Telnet login
# Set the level of commands accessible to the VTY 0 user to 2.
[3Com] user-interface vty 0
[3Com-ui-vty0] user privilege level 2 
# Enable the Telnet service on VTY 0.
[3Com-ui-vty0] protocol inbound telnet 
# Set the number of lines that can be viewed on the screen of the VTY 0 user to 
30.
[3Com-ui-vty0] screen-length 30 
PC
Switch
RS-232
Configuration cable
Console port
Product series 
Software version Hardware version 
Switch 5500 
Release V03.02.04 
All versions 
Switch 5500G
Release V03.02.04 
All versions 
Switch 4500
Release V03.03.00 
All versions
Switch 4210
 Release V03.01.00 
All versions