3com 5500G ユーザーズマニュアル
![3com](https://files.manualsbrain.com/attachments/960452ff43b9899cbcffced60c87abf956e7967a/common/fit/150/50/f6ac125d7af2cf40fec58935fa6d4bf71457a57efe50bee91208a434f325/brand_logo.jpeg)
232
C
HAPTER
25: M
IRRORING
C
ONFIGURATION
G
UIDE
Network Diagram
Figure 69 Network diagram for remote port mirroring
Networking and
Configuration
Requirements
The departments of a company connect to each other through Switch 5500s:
■
Switch A, Switch B, and Switch C are Switch 5500s.
■
Department 1 is connected to Ethernet 1/0/1 of Switch A.
■
Department 2 is connected to Ethernet 1/0/2 of Switch A.
■
Ethernet 1/0/3 of Switch A connects to Ethernet 1/0/1 of Switch B.
■
Ethernet 1/0/2 of Switch B connects to Ethernet 1/0/1 of Switch C.
■
Data monitoring device is connected to Ethernet 1/0/2 of Switch C.
The administrator wants to monitor the packets sent from Department 1 and 2
through the data monitoring device.
through the data monitoring device.
Use the remote port mirroring function to meet the requirement. Perform the
following configurations:
following configurations:
■
Use Switch A as the source switch, Switch B as the intermediate switch, and
Switch C as the destination switch.
Switch C as the destination switch.
■
On Switch A, create a remote source mirroring group, configure VLAN 10 as
the remote-probe VLAN, ports Ethernet 1/0/1 and Ethernet 1/0/2 as the source
ports, and port Ethernet 1/0/4 as the reflector port.
the remote-probe VLAN, ports Ethernet 1/0/1 and Ethernet 1/0/2 as the source
ports, and port Ethernet 1/0/4 as the reflector port.
■
On Switch B, configure VLAN 10 as the remote-probe VLAN.
■
Configure Ethernet 1/0/3 of Switch A, Ethernet 1/0/1 and Ethernet 1/0/2 of
Switch B, and Ethernet 1/0/1 of Switch C as Trunk ports, allowing packets of
VLAN 10 to pass.
Switch B, and Ethernet 1/0/1 of Switch C as Trunk ports, allowing packets of
VLAN 10 to pass.
■
On Switch C, create a remote destination mirroring group, configure VLAN 10
as the remote-probe VLAN, and configure Ethernet 1/0/2 connected with the
data monitoring device as the destination port.
as the remote-probe VLAN, and configure Ethernet 1/0/2 connected with the
data monitoring device as the destination port.
Applicable Products
Switch A
Eth1/0 /3
Dept. 1
Dept. 2
Eth1/0 /1
Switch B
Switch C
Eth1 /0/1
Eth1 /0/2
Eth1 /0/1
Eth1 /0/2
Reflector
port
Eth1/0/4
Eth1/0/2
Data monitoring device
Product series
Software version
Hardware version
Switch 5500
Release V03.02.04
All versions
Switch 5500G
Release V03.02.04
All versions
Switch 4210
All versions