3com 4200G ユーザーズマニュアル

ページ / 336
318
C
HAPTER
 34: I
NFORMATION
 C
ENTER
 C
ONFIGURATION
 G
UIDE
info-center source IP channel 0 trap state off
undo info-center source default channel 0 
Precautions
None
Displaying the Time 
Stamp with the UTC 
Time Zone
Network Diagram
Figure 109   Network diagram for displaying the time stamp with the UTC time zone
 
Networking and
Configuration
Requirements
The switch is in the time zone of GMT+ 08:00:00.
The time stamp format of output log information is date.
UTC time zone will be added to the output information of the information 
center.
Applicable Products
Configuration Procedure
# Name the local time zone z8 and set it to eight hours ahead of UTC time.
<3Com> clock timezone z8 add 08:00:00 
# Set the time stamp format of output log information to date.
<3Com> system-view
[3Com] info-center timestamp loghost date 
# Configure to add UTC time to the output information of the information center.
[3Com] info-center timestamp utc 
Complete Configuration
#
info-center timestamp utc 
Precautions
None
Network
Log host
Switch
Product series 
Software version 
Hardware version 
Switch 5500
Release V03.02.04 
All versions
Switch 5500G
Release V03.02.04 
All versions
Switch 4500
Release V03.03.00 
All versions
Switch 4210
Release V03.01.00 
All versions