Configuring & Monitoring the Switch  71
Configuring Port Mirroring
You can mirror the traffic being switched on any port for the purposes of 
network traffic analysis and connection assurance. When Port Mirroring 
is enabled, one port becomes a monitor port for any other port within the 
stack. Note that the source and target ports must be configured within the 
same VLAN and be operating at the same speed. If the target port is 
operating at a lower speed, the source port will be forced to drop its 
operating speed to match that of the target port.
To configure port mirroring, do the following:
1.  Select Device Control Menu from the Main Menu.
2.  Select Mirror Port Configuration.
3.  For the Mirror Source Port, select the stack unit and port number. 
4.  For the Mirror Target Port, select the stack unit and port number. 
5.  Set the Status field to ENABLED.
6.  Connect a traffic analyzer or RMON probe to the mirroring port.
Downloading a Software Upgrade
You can upgrade the operational software in the VH-2402S switch without 
physically opening the switch or being in the same location. The software 
storage sector in the flash memory of the switch is reprogrammable, 
allowing you to easily download software feature enhancements and 
problem fixes to the switch from a local or remote location.
Software can be downloaded to the switch in two ways: 
Via the serial port. This procedure is an out-of-band operation that 
copies the software through the serial port to the switch. This 
operation takes approximately 10 minutes and requires minimal 
configuration.
Via TFTP download. This procedure uses a TFTP server connected 
to the network and downloads the software using the TFTP protocol. 
A TFTP download is much faster than a serial download, requiring 
only a few seconds, and can be used to upgrade an  switch that is not 
VH-2402S physically proximate. The disadvantage is that this 
method requires a TFTP server and additional setup.