VLAN Redirect Configuration Screen
6-20
Port Configuration Menu Screens
10.Use the SPACE bar to select either the ADD or DEL (delete) option. Press ENTER. This adds 
or deletes the selections for the Source Port, Destination Port, Frame Format, and Redirect 
Errors made in steps 1 through 8 and also updates the screen.
11.Use the arrow keys to highlight SAVE at the bottom of the screen. Press ENTER. The message 
“SAVED OK” displays. This saves the new settings and updates the Source Port and Destination 
Port read-only fields.
6.7
VLAN REDIRECT CONFIGURATION SCREEN
When to Use
To redirect frames in a 6C105 chassis from one or more source VLANs to one destination port on 
the switch module. Frames received on a source VLAN can be redirected and transmitted in the 
frame format in which they are received (normal), or they can be redirected with a VLAN Tag 
(TAGGED) or without a VLAN Tag (UNTAGGED). Also, any errored frames received dropped. 
For
 example, VLAN 1 can be set as the source VLAN with VLANs 2 and 5 as the destination 
VLANs. Frames from VLAN 1 are then automatically redirected to VLANs 2 and 5 according to 
the configured frame format, and VLAN frames with errors 
are dropped
.
TIP: If more than 1 port is being redirected, repeat steps 1 through 10 for each 
additional setting. Then go to step 11 to save all the new settings at once.
If an entry is to be changed, delete the entry, save the screen, then recreate the entry 
with its new settings.
NOTES: Any combination, up to 128 total, of port redirect instances can be configured 
on the Port Redirect Configuration screen, and/or VLAN redirect instances on the VLAN 
Redirect Configuration screen. Up to 24 instances can be configured as remote 
instances to other modules in the chassis. Remote instances are instances that are 
mapped from one module to another within the same chassis. 
If the module has an optional ATM interface installed, ATM Permanent Virtual Circuits 
(PVCs) redirect entries should also be considered as part of the 128 maximum redirect 
entries for the module.
NOTE: The switch module supports a maximum of 128 redirect entries configured 
including VLAN redirect, and port redirect. This also includes any ATM Permanent 
Virtual Circuits (PVCs) redirect entries if the module has an optional ATM interfaces 
installed.