SMC Networks 100 ユーザーズマニュアル

ページ / 90
A-1
A
PPENDIX
 A
T
ROUBLESHOOTING
Diagnosing Switch Indicators 
Troubleshooting Chart
Symptom
Action
Power LED is Off
Internal or redundant power supply has failed or 
is disconnected.
Check connections between the switch, the 
power cord, the wall outlet, and the RPU if you 
are using one.
If the switch is installed in a rack, check the 
connections to the punch-down block and patch 
panel. 
Contact SMC Technical Support.
Power LED is Flashing
The switch is either downloading firmware or 
running the Power-On Self-Diagnostics Test 
(POST). If this LED does not stop flashing, then 
POST has failed, and you should contact SMC 
Technical Support.
Link LED is Off
Verify that the switch and attached device are 
powered on.  
Be sure the cable is plugged into both the switch 
and corresponding device.  
Verify that the proper cable type is used and its 
length does not exceed specified limits.  
Check the adapter on the attached device and 
cable connections for possible defects. Replace 
the defective adapter or cable if necessary.